Concrete nondestructive testing technology-2
时间:2019-08-12 10:42 来源:未知 作者:admin 点击:次
Radar method for detecting internal defects and reinforcement positions of concrete ![]() Semi-cell method for detecting corrosion of steel bars Electromagnetic method to detect the position of steel bars ![]() The half-cell method detects dangerous areas of corrosion of steel bars. If the steel bar is not corroded, the passivation state of the surface is good, the half-cell potential is high, and the potential measured by the copper/copper sulfate standard half-cell is generally not lower than -100 mv, and in severe corrosion, the measured potential value may be lower than -400mv. (责任编辑:admin) |
- 上一篇:Transmission line fittings crimping quality X-ray inspection
- 下一篇:The latest industrial digital X-ray imaging technology you w