Crack depth detection of concrete structural members
时间:2019-08-08 11:22 来源:未知 作者:admin 点击:次
Crack depth detection of concrete structural members (1) Single-sided flat measurement method---shallow crack ![]() (2) Double-sided oblique measurement method---shallow crack ![]() Drilling pair measurement method---deep crack ![]() ![]() When the crack depth is detected by ultrasonic method, it is required that there is no water and mud in the crack, because the signal quality obtained by the flat test method and the oblique test method is relatively poor, and the water and mud in the crack reduce the attenuation effect of the crack on the ultrasonic wave. It makes it more difficult to find the defect signal in the detection. In addition, the steel bars in the reinforced concrete members interfere with the propagation of the ultrasonic waves, so that the defect signals are not obvious. When the steel bars are thick and dense, it is not advisable to use ultrasonic methods to detect the crack depth. (责任编辑:admin) |